Control Panel

HCA-2_4_8 and D
STANDARD FEATURES:
- UL864 9th Edition / NFPA Compliant,
- Fully programmable using simple menu options,
- Simple, single board construction Installer friendly,
- Built-in two-line (16 Characters for each line) LCD display provides easy to read information,
- 15 Key control buttons for easy programming, reset and silencing,
- Real time clock,
- Event History log (256 events) with Date/Time stamp, which can be viewed from LCD display,
- Compatible with wide range of detection devices,
- 4 Programmable Supervised NAC outputs,
- 6.5 Amp power supply,
- Switchable 120/240VAC 50/60 Hz Power supply,
- 5 Programmable output patterns for NAC circuits,
- Gentex Sync Protocol Built-in,
- Supports Releasing of Agents on HCA-4 & HCA-8 models,
- Three programmable general purpose relays,
- Dedicated alarm and trouble relays,
- Built-in walk test feature Panel Dimension: 14.57″ (W) x 15.47″ (H) x 4.41″ (D),
- Supports up to two 12V, 18Ah Backup batteries,
- Supports one Remote Annunciator via RS-485.
Download Data Sheet

FireNET Plus
STANDARD FEATURES:
- Analog design using Hochiki’s advanced DCP protocol for fast communication,
- Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop,
- Uses standard wire, no-shielded or twisted pair required on SLC loops,
- Integrated digital alarm communicator (DACT) with Contact ID and SIA reporting formats,
- Programmable sensitivity levels by device,
- Alarm Verification feature,
- Automatic daily calibration & drift compensation routine,
- Large 8-line x 40-character LCD display (320 char.),
- 1 or 2 loop (option),
- RS-485 bus for panel network (option),
- Built-in RS-232 interface for programming via a PC,
- 3 on board programmable Form C relays rated at 1 amp at 30VDC,
- 2 auxiliary power outputs, each rated 360mA at 24 VDC,
- Loop Explorer Windows® configuration utility,
- Auto-learn feature,
- 500 network wide software zones,
- Network Capability of up to 64 panels (option),
- Built in help and alarm information screens,
- 2 on-board Class B (style Y) NAC circuits rated at 2.3 amps each (Special Application) and 1.6 amps each (Regulated continuous),
- Gentex, System Sensor, Wheelock, and Amseco NAC sync protocol built-in,
- Automatic day/night sensitivity modes,
- Fire Drill test function,
- Walk Test function,
- Powerful & versatile Cause & Effect wizard including:
– Cause & Effect action
– Disable function configuration
– Test mode configuration
Download Data Sheet